Parker Hannifin
78 Programmer’s Guide
REM the desired master acceleration
ACC 20
REM the desired master deceleration ramp
DEC 20
REM the desired master stop ramp (deceleration at end of move)
STP 20
REM the desired master velocity
VEL 10
REM the desired acceleration versus time profile.
JRK 0
Resources Reserved for Generated Code
The Configuration Wizard reserves controller resources based on the
controller, its firmware version, and the features you enable. When
you save the configuration, the wizard generates AcroBASIC code
and saves it to specific user and PLC programs.
The Configuration Wizard saves all configuration data to a Setup.8K
file. Depending on which controller and the firmware version, it may
also save Drive I/O or Configuration Wizard data to various user and
PLC program files.
NOTE: Do not edit the source files generated by the Configuration
Wizard.
Firmware Versions 1.18.15 and up (ACR9000 only)
The wizard generates AcroBASIC code and places it in the Setup.8K
file. The Prog15.8K file contains the configuration wizard data.
Firmware Versions Up to 1.18.14 (All ACR Controllers)
The wizard generates AcroBASIC code and places it in the Setup.8K
file. The Prog7.8K, PLC5.8K, PLC6.8K, and PLC7.8K files contain the
configuration wizard data and code for Hardware Limits, Software
Limits, and Drive Fault (hardware-input based drive fault, or
software-based following error drive fault) features.
PLC programs have limited memory space. If the resulting code
exceeds the limit for a PLC program, the Configuration Wizard splits
it among several PLC programs. The wizard uses the PLC5.8K file first,
and uses the PLC6.8k and PLC7.8k files as needed.