Parker Hannifin
160 Programmer’s Guide
The Node ID must be set by the user to match the node ID settings
on the actual nodes. All other node information is filled in by the
controller after the network is started. The node information is saved
with the ESAVE command, and user applications may use it to verify
expected network configuration, or make run time application
decisions.
This information could serve as a source for a front-end software GUI
that displays bus and node status, although no configuration would
be possible. Another possibility would be to implement a sort of
“Network Configuration Verify” command that would allow the
application to easily verify that the configuration is the same every
time.
In the table below, nodes are numbered 0-3, like all other ACR
objects. This is the node number, from the ACR9000 point of view.
The node ID is the setting on that node’s DIP switch, and must be
between 1 and 127, but may not conflict with the chosen Master
node ID.
Description/Node number 0 1 2 3
Node Id 33024 33040 33056 33072
Number of Digital Inputs
(bytes)
33025 33041 33057 33073
Number of Digital Outputs
(bytes)
33026 33042 33058 33074
Number of Analog Inputs 33027 33043 33059 33075
Number of Analog Outputs 33028 33044 33060 33076
Health Type (0=not present,
1=heartbeat, 2= lifeguarding)
33029 33045 33061 33077
Node state (0=dead, 1=live) 33030 33046 33062 33078