OWNER
VESSEL
RADIO CALL SIGN
UIN #
Vista de página 0
1 2 3 4 5 6 ... 30 31

Resumo do Conteúdo

Página 1

OWNER VESSEL RADIO CALL SIGN UIN #

Página 2

Y1-03-0250 Rev. B 9 GPS Interface Stowage Port Category 2 – QuickDraw™ Bracket Category 1 – SeaShelter™3 Bracket Spring Release Knob HydroFix

Página 3

Y1-03-0250 Rev. B 10 3. Activating your beacon Overview Category I beacons are designed to be automatically deployed and activated in th

Página 4

Y1-03-0250 Rev. B 11 Category I beacons-Automatic deployment and activation If the vessel sinks, the HydroFix™ HRU frees the beacon from the bracket

Página 5

Y1-03-0250 Rev. B 12 Category I and II Beacons-Manual deployment and activation Both Category I and II beacons can be manually deployed by removing t

Página 6

Y1-03-0250 Rev. B 13 TIPS FOR OPTIMUM DEPLOYMENT OF AN ACTIVATED BEACON: When activating and deploying your beacon in an emergency, DO NOT: // Hold

Página 7

Y1-03-0250 Rev. B 14 5. False alarms To prevent false alarms, it is important to be aware of how your beacon can be activated. An ACR 406 MHz

Página 8

Y1-03-0250 Rev. B 15 STEP THREE - INSTALLING THE BEACON 1. Marking battery and Hydrostatic Release Unit expiration dates NOTE: It is the beacon owne

Página 9

Y1-03-0250 Rev. B 16 Visually inspect the area surrounding the mounting bracket installation site for hidden hazards or obstacles that may have been

Página 10

Y1-03-0250 Rev. B 17 3. Category I bracket The SeaShelter3™ Category I bracket has five pre-drilled screw holes to use for securing the bracket to

Página 11

Y1-03-0250 Rev. B 18 4. Category II bracket Category II brackets are designed to hold the beacon securely in place. The beacon must be manually

Página 12

Y1-03-0250 Rev. B 1 NOTE re: Applicable products This manual supports all configurations of Satellite3 406™/ RLB-38 b

Página 13

Y1-03-0250 Rev. B 19 5. Installing the Optional optical GPS interface cable The beacon is fitted with an optical interface to connect with an

Página 14

Y1-03-0250 Rev. B 20 STEP FOUR - MAINTAINING THE BEACON 1. Safety DOs and DON’Ts On a routine basis aboard ship, DO NOT: // Hold or carry the bea

Página 15

Y1-03-0250 Rev. B 21 Always refer battery replacement and any other beacon service to a factory authorized Service Center. Find a Center near

Página 16

Y1-03-0250 Rev. B 22 6. Changing ownership or contact information As the owner of the beacon, it is your responsibility to advise the national autho

Página 17

Y1-03-0250 Rev. B 23 To remove the expired HRU When opening the SeaShelter3™ lid, note that the beacon is installed with the lanyard face in. Pull t

Página 18

Y1-03-0250 Rev. B 24 CAUTION: Do not force the lid closed. If the lid does not close easily, check to see that the beacon is properly install

Página 19

Y1-03-0250 Rev. B 25 APPENDIX A - USING AND TESTING THE GPS SYSTEMS 1. How the external GPS interface works The beacon is fitted with an opt

Página 20

Y1-03-0250 Rev. B 26 bypasses the normal, programmed, waiting time of 20 minutes for the automatic update of GPS position data. If no va

Página 21

Y1-03-0250 Rev. B 27 APPENDIX B - THE COSPAS-SARSAT SYSTEM 1. General overview EPIRBs transmit to the satellite portion of the Cospas-Sarsa

Página 22

Y1-03-0250 Rev. B 28 APPENDIX C - TECHNICAL SPECIFICATIONS GENERAL/ ENVIRONMENTAL Beacon size (without antenna) 17.7 H X 10.67 W X 9.09 D cm (6.97 X

Página 23

Y1-03-0250 Rev. B 2 Table of Contents STEP ONE - REGISTERING YOUR BEACON ____________________________ 3 STEP TWO - HOW THE BEACON WORKS _____

Página 24

Y1-03-0250 Rev. B 29 APPENDIX D - WARRANTY, USEFUL LIFE POLICY, NOTICES 1. Limited Warranty This product is warranted against factory defects in mat

Página 25

Y1-03-0250 Rev. B 30 EC DECLARATION OF CONFORMITY ACR Electronics hereby declares that the following product is in conformity with Cou

Página 26

Y1-03-0250 Rev. B 3 STEP ONE - REGISTERING YOUR BEACON 1. Why is registration important? As the owner of this 406 MHz beacon, it is mandatory that

Página 27

Y1-03-0250 Rev. B 4 2. What country should I register in? Register your beacon with the EPIRB national authority of the country for which th

Página 28 - Y1-03-0250 Rev. B 27

Y1-03-0250 Rev. B 5 Registration outside of the United States In countries other than the United States, 406 MHz beacons are registered with that c

Página 29 - Y1-03-0250 Rev. B 28

Y1-03-0250 Rev. B 6 STEP TWO - HOW THE BEACON WORKS 1. How your beacon brings help 406 MHz beacons are a type of portable emergency equipme

Página 30 - Y1-03-0250 Rev. B 29

Y1-03-0250 Rev. B 7 2. Anatomy of your beacon NOTE: When unpacking your beacon, it is recommended that you save the original packaging for re-us

Página 31 - EC DECLARATION OF CONFORMITY

Y1-03-0250 Rev. B 8 Top View Switch Positions Strobes Optional GPS Interface Antenna Green LED Red LED Activation/ Test Switch